When you multiply these number across, you find the true magnification for the microscope. It is important to keep these numbers handy for the chart that I’ll be showing you in the following slides. Physics: In physics, stage micrometers play a crucial role in measuring the size of objects like crystals and defects in materials. This information is used to investigate material properties and develop cutting-edge technologies. For instance, scientists can use stage micrometers to analyze the size and distribution of defects in materials, affecting their mechanical and electronic properties. Stage micrometers find diverse applications across various scientific and industrial fields, owing to their precision and versatility. Here are some specific examples of how stage micrometers are used in different areas: Use a Soft Cloth for Cleaning: Clean the stage micrometer after each use using a soft, lint-free cloth. Avoid using harsh chemicals or solvents, as they can damage the delicate components. Each type of stage micrometer has its advantages and applications, making them valuable tools for researchers, scientists, engineers, and quality control professionals working in diverse fields and industries. The choice of stage micrometer depends on the specific measurement requirements and desired accuracy for a particular task. How to Use Stage micrometer – Procedure of Stage micrometer

A more highly corrected and refined version of the Ramsden design, known as the Kellnereyepiece, employs an achromatic doublet for the eye lens to more fully correct chromatic aberration of the field lens. Kellner eyepieces (not illustrated in Figure 3) also feature a high eye point, which is useful to operators wearing eyeglasses, but they introduce a small degree of distortion to the image. Because the lower focal plane is external to the optical system in the Kellner eyepiece, aberrations affect the intermediate image and eyepiece reticle equally, and therefore, this eyepiece style is ideal for conducting accurate measurements with the microscope. Many infinity-corrected microscopes are equipped by the manufacturers with Kellner-style eyepieces, which feature a removable fixed diaphragm tube threaded into the lower portion of the eyepiece barrel. Removal of the diaphragm tube and installation of a reticle can be easily accomplished in a few minutes without disassembly of the eyepiece internal lens element mounts. That’s a lot easier than pulling out a calculator every time you want to measure a single particle. An important factor that should be considered as a potential source of measurement error is the subjectivity involved in setting a reference line at the edge of a specimen feature. It should be borne in mind that measurements conducted in the microscope utilize an optical image of the specimen and not the specimen itself. The contrast mechanism employed in imaging, the type and quality of illumination, and the numerical aperture and other properties of the objective all affect the appearance of specimen feature edges from which measurements are often taken. In addition, if diffraction artifacts are present in the image, the selection of feature edges for placement of a measurement reference line can be highly uncertain. Calibration of an eyepiece reticle (determination of the micrometer graduation relationship) for a particular objective is typically conducted by following the recommended procedure described below (also see Figure 4). Note that calibration of an eyepiece reticle holds only for the specific objective/eyepiece combination being tested, and for the specific mechanical tube length of the microscope. To unnecessarily avoid repeating the procedure, the calibration information for each combination should be recorded and stored in a convenient location near the microscope workstation. After the eyepiece reticle has been calibrated with the stage micrometer, specimen linear dimensions can be measured. For all measurements, the highest magnification objective should be chosen that enables the entire specimen feature of interest to fall within the span of the reticle scale. Orient the reticle scale to coincide with the contour of the specimen region under scrutiny. Next, move the specimen until the left edge coincides with a numbered line on the eyepiece reticle, and count the number of scale divisions spanned by the target region. Carefully estimate any fraction of a division. To increase accuracy, conduct several measurements on large specimens. When circular or oval specimens are being measured (such as blood cells, yeast, bacteria, etc.), record the dimensions of at least 20 candidates from different fields. The specimen being examined in Figure 4(c) is a human scalp hair shaft, which is approximately 93 micrometers in diameter (measured with a calibrated reticle, as discussed above).

 

Second, you will want to determine your dominant eye, and place the reticle on that side. Eyepieces are usually removable and interchangeable with one another. If you have this option on your microscope, the reticle—or the scale bar—should be placed on the side of the user’s dominant eye.

This is called a stage micrometer, and is in effect a very accurately etched ruler in the centre of a microscope slide. Usually the scale is 1 mm divided into 100 parts or 1cm divided into 1000 parts.Calibration of Microscopes: Stage micrometers serve as calibration standards for microscopes, ensuring accurate measurements when using the microscope for various applications. For instance, if the object’s length is 5 divisions on the stage micrometer, and the eyepiece graticule magnification is 10x, the actual size of the object is 50 µm.

Horizontal and vertical reticle scales (Figure 5(b) through Figure 5(g)) are manufactured in a wide spectrum of configurations to suit any linear measurement requirement. Graduated horizontal scales (Figure 5(b)-5(e)) are the most common, and usually consist of a 10-millimeter scale subdivided into 8, 10 or 100 divisions. These reticles are useful for measurements of all specimen feature sizes, and often contain reference marks to aid calibration and measurement. Crossed micrometer scale reticles (Figure 5(f) and 5(g)) are employed for two-dimensional linear measurements, or for convenience when separate measurements are taken in a vertical and horizontal direction. Tapered gauge reticles (Figure 5(h)) consist of several ruled line pairs that have differing gaps between the lines in each pair. Engraved beside the line pair is a reference number for calibration of the reticle with a stage micrometer. Tapered gauge reticles are convenient for measuring the size of mixed fibers and similar specimens that have repeating feature dimensions. On to the fifth, and final, step of calibrating your objectives: create a sizing chart for your work station. Instead of making calculations every time you measure a particle, create a cheat sheet to expedite your observation process.Stage micrometers offer several advantages that make them invaluable tools for accurate measurements in microscopy and various scientific fields. Here are some key advantages of using a stage micrometer: Multi-Scale Stage Micrometers: Multi-scale stage micrometers have multiple scales on a single slide, each calibrated in different units. This enables users to measure objects using various measurement systems. User-Dependent Accuracy: The accuracy of stage micrometers heavily relies on proper alignment and precise measurements by the user. Carelessness can lead to inaccurate results.