Sentinel X300 System Cleanser 1Ltr

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

What next? Add Sentinel X100 inhibitor, to prevent corrosion and the build-up of limescale, the main causes of central heating and boiler inefficiency. It is recommended that Sentinel X400 High Performance Cleaner is used in accordance with standard cleaning and commissioning protocols such as BSRIA Guide “Pre-Commission Cleaning of Pipework Systems” or similar Water Treatment Guidelines from industry organisations such as the Industrial & Commercial Energy Association (ICOM). In this scenario, the system may benefit from a manual flush using with X300. The system I’m dealing with is older than 6 months Why? Contamination from the manufacturing and installation processes can accelerate corrosion of new components. According to UK Building Regulations Part L Domestic Heating Compliance Guide, a central heating system should be thoroughly cleaned and flushed out before the installation of a new boiler.

Not sure what cleaner is best for the job? We’ve created a handy cleaner comparison to help you choose the right cleaner for your system. Sentinel X300 Cleaner for New Systems should be dosed at 1% of system volume, i.e. 1 litre per 100 litres of system water. A few examples of the kind of debris that can be found in new systems include copper swarf, flux residues, casting sands and rust. Other contaminants can include greases and stamping oils used in the manufacturing process, sometimes applied excessively. When introduced into a central heating system, these materials can cause problems such as corrosion. Recommended dosage: Ideal for pre-dosing, 1 litre of X400 is sufficient to treat a typical domestic system of up to 10 radiators. Circulate from 2 hours to 3 or 4 weeks depending on system fouling.

Solutions

As for new systems, X300 Cleaner for New Systems is designed to target installation and manufacture debris and contaminants. Once cleaned, it will passivate the metal surfaces and prevent copper deposition.

litre, 1 300ml aerosol or 1 275ml tube of Sentinel X400 High Performance Cleaner is sufficient to treat a typical domestic system of up to 10 radiators. Larger systems should be dosed with twice this amount. quart of Sentinel X400 is sufficient to treat a typical residential system of 25 gallon. Larger systems should be dosed at 1% of system water. To clean an existing system, Sentinel X400 should be circulated, preferably at normal operating temperature, with all valves open and the pump turned to maximum flow for a minimum period of 2 hours or until satisfactory performance is restored. Recommended dosage: 1 litre of X300 is sufficient to treat a typical domestic system of up to 10 radiators. Circulate from 1 hour to 7 days for maximum performance. After cleaning, the system should be drained and flushed until the water runs clear. On refilling, the system should be treated with Sentinel X100 Inhibitor or Sentinel X500 Inhibited Antifreeze.

The solution

If it is not possible to heat the water, the circulation time should be extended to at least 24 hours. After cleaning, the system should be drained and flushed until the water runs clear. On refilling, the system should be treated with Sentinel X100 Inhibitor or Sentinel X500 Inhibited Antifreeze.

Sometimes a more general clean is required, aimed at removing iron oxide and limescale deposits from pipework, heat exchangers and radiators. X800 Fast Acting Cleaner is ideal for these purposes, designed for use in conjunction with powerflushing equipment, but also proving a highly effective cleaner when manually flushed, too. It is effective both hot and cold. When might I need Deposit Remover?Apply to: Remove residual flux, grease, oil and manufacturing & installation debris in systems under six months old To clean an older system in accordance with BS 7593, this product should be circulated (preferably at normal operating temperature, with all valves open and the pump turned to maximum flow) for a minimum period of 2 hours or until satisfactory performance is restored. Use in conjunction with a powerflushing device to achieve a more rapid clean. It is recommended that Sentinel X300 Cleaner for New Systems is used in accordance with standard cleaning and commissioning protocols such as BSRIA Guide “Pre-Commission Cleaning of Pipework Systems” or similar Water Treatment Guidelines from industry organisations such as the Industrial & Commercial Energy Association (ICOM). If a system has not been cleaned prior to use, all of the aforementioned issues for new systems will be present, with the installation debris causing issues and damage to the system. Rapid cleaning may be carried out if Sentinel X400 is used in conjunction with a power-flushing device.

Sealed Systems: If the system is empty, add to any convenient point before filling. If full, use a Sentinel Dosing Vessel to inject via the filling loop or other access point. X300 Cleaner for New Systems is designed to target excess flux residues, greases, and oils in addition to installation debris and sludge. Not only this, but X300 passivates the metal surfaces and helps to prevent copper deposition, a common cause of pinhole corrosion in radiators. Ideally, the product should be added at the first filling of the system. The water should then be circulated at normal operating temperatures for 2 hours before being flushed out. If you are using cold water, leave to circulate for 24 hours. Powerflushing is not necessary when using this product. The system I’m dealing with is not new, but is less than 6 months old For details of how to dose using the Rapid-Dose format of this product, please watch the Rapid-Dose video. How does it work? Contains a specialised dispersant to penetrate and lift sludge. Holds sludge in suspension ready for flushing.

Sentinel X400 High Performance Cleaner should normally be dosed at 1% of system volume, i.e. 1 litre per 100 litres of system water. For systems with severe fouling, the dosage rate can be increased up to 5%. When using concentrate gel, add directly to the heating system either via a radiator air bleed valve, or via the fill loop using the appropriate adaptor and a suitable caulk gun. Apply to: Restore circulation and effectiveness in systems older than six months that have a significant amount of corrosion debris causing poor circulation and cold spots. Prepare for the installation of new components. Sentinel X300 Cleaner for New Systems should be circulated, preferably at normal operating temperature, with all valves open and the pump turned to maximum flow for a minimum period of 3 hours. Its formulation also contains agents to ensure the protection of system metals against corrosion during the cleaning as well as preparing the installation for the addition of Sentinel X100 Inhibitor.