276°
Posted 20 hours ago

Worcester 87161157410 Heat Exchanger, Greenstar junior, greenstar i system

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

if boiler works fine with the cover off and the fan is working fine then replace the air pressure switch (ISP). The part number is 87161044610 Mind you, we don’t necessarily mean a leak in the boiler itself. Any leak throughout your central heating will cause a boiler to show a dropping pressure gauge. This could be a pin-hole in a radiator, a loose connection on a rad valve, or even a weak soldering joint on the copper pipe. This primary heat exchanger is guaranteed against faulty materials or workmanship for a period of 120 calendar months from the date of installation subject to the following conditions and exceptions. The boiler recognises this and displays a fault code, likely A281 or EA338. The Fix for a Leaking Boiler Bosch Thermotechnology Ltd. will not accept responsibility for damage caused by faulty installation, neglect, misuse or accidental damage the non-observance of the instructions contained in the Installation and Users Instructions leaflets.

In most cases, fixing the underlying problems will require the assistance of a Gas Safe registered engineer. How do I reset my Worcester boiler? Combi 24 HE - Radiators are getting hot when hot water tap is opened. Faulty Hydraulic Venturi 24805 If the diverter valve doesn’t sound like the issue, you can read more about “Worcester boiler no hot water” in our full guide on the subject. #3 – Your Boiler Is Leaking

That the householder may be asked to prove the date of installation, that the appliance was correctly commissioned and that the annual service has been completed to manufactures requirements to the satisfaction of Bosch Thermotechnology Ltd, when requested. On the early Worcester Greenstar range the Junior and Si(and Ri) had a condensate trap. The condensate traps job is to safely collect and release the condensation created by a condensing boiler. On later Junior and Si models this was upgraded to a better type of trap which Worcester likes to refer to as a Siphon. As a rule, if your boiler problems relate to a loss of pressure, you have a leak. Sure, it might not be visible, but it’s there somewhere. Products installed from 1st January 2007 are covered within these terms and conditions, which are as follows: It’s a daunting issue when you own a Worcester Bosch boiler: no hot water flowing despite things appearing as they should.

If your boiler is out of warranty and needs a diverter valve replacing, it might be wise to invest that cash in a new appliance with a long boiler warranty. The cheapest place to find a replacement Worcester Bosch boiler online currently is Heatable, where these boilers are usually offered at competitive prices and with 10-year warranties. Condensing boilers, like all modern ones including those made by Worcester Bosch, have a condensate pipe. This pipe vents harmful gases from your property. Richard is very prompt, reliable, & honest. I’d definitely use him again & recommended him to anyone.” Distribution losses may be disregarded if all of the pipe work is located entirely within the heated space of the dwelling when losses are incurred outside the heated space such as when the boiler is located in a garage then add up to 10% for the calculated space heating.

Top Sellers

Worcester24CDI RSF Combi boiler shuts off after about 10 seconds when itstarts making a loud kettling sound If the system is of a sealed primary type then it must be connected as per the installation instructions with all joints capable of sustaining a pressure of up to 3 bar. System cleansing Before we finish, let’s go over a few FAQs that often surround Worcester Bosch boiler faults. Why is my Worcester boiler not firing up? To replace the hydraulic assembly you will need to drain the boiler and isolate the cold water supply For example, if there’s insufficient gas supply, the ignition electrodes are faulty, or the burner is clogged, the boiler will fail to fire up.

The boiler must be sized in accordance with BS5449 and the whole house boiler sizing method, so to meet the hot water and heating demands of the property. This is based upon the following:Note: Once you’ve fixed the water leak, make sure you top up the boiler’s water levels so that the water pressure is around 1.3 bar)

Asda Great Deal

Free UK shipping. 15 day free returns.
Community Updates
*So you can easily identify outgoing links on our site, we've marked them with an "*" symbol. Links on our site are monetised, but this never affects which deals get posted. Find more info in our FAQs and About Us page.
New Comment