The most common source of false alarms in smoke detectors is contamination (such as dust and small insects) within the sensor chamber. Cleaning the unit by either vacuuming around the central detection chamber or blowing it out with the cold setting on a hair dryer normally resolves this issue. The Aico EI146E smoke alarm provides a sealed mesh to guard against insects as well as automatic compensation for dust. It also boasts an optical proven smoke chamber that ensures advanced fire detection while reducing any unwanted tripping. As this smoke chamber will automatically self-test every forty seconds, it gives warning in advance about any unit degradation. Ei146E features a brand new updated aesthetic, with cleaner, more modern styling alongside a new, slimmer construction than its predecessor the Ei146RC. Features of Aico EI146E Make sure you look after your smoke alarms by changing batteries and testing the unit on a regular basis. We offer free reminder services to ensure you remember to do your alarm test and to change the battery.

Mains powered Ei Electronics smoke and heat alarms require a 230V AC power supply and up to 12 alarms can be hardwire interlinked in one system. One of the Ei168 radio bases flashes amber light every 10 seconds. All other bases in the group are fine. Solution The alarm is fitted with a Test/ Hush button to facilitate frequent testing of the alarm and system and The silence function allows the alarm/ system to be silenced in the case of a false or nuisance alarm, e.g. cooking fumes. The Ei146E Optical Smoke Alarm is fitted with a mains power on™ green LED indicator and an alarm™ red LED indicator.It is possible to interconnect the EI146E alarm with other accessories and alarms via a hard-wired connection or, to minimise disruption and mess, by a wireless RadioLINK interconnection. The EI146E optical smoke alarm is also compatible via wireless interconnection with the RadioLINK Ei168RC Base. The Aico Ei146E Optical Smoke Alarm is best for slow smouldering fires, such as, burning sofas or household appliances. This device uses a large capacity, proven optical sensor chamber that features built-in mesh screen for reduced insect and dust contamination The Aico EI146E mains powered optical smoke alarm delivers outstanding functionality in a modern, slim casing to blend seamlessly with contemporary interiors. With its mains powered operation, the EI146E optical smoke alarm can effortlessly detect smouldering, slow fires that are typically caused by electrical or sofa fires. When sufficient smoke enters the arm, the fire warning is sounded, alerting the property’s occupants. The new alarm can interlink with any other Ei140/140RC series alarms remaining in your system, along with many other Ei Electronics / Aico models. The more modern optical sensor technology in the Ei146e is less susceptible to false alarms, making it suitable for use in a wider range of locations such as rooms adjacent to kitchens, hallways, landings, bedrooms, and living areas. Beeping or chirping is normally due to low battery power in the alarm. This beeping most commonly starts at night due to the drop in temperature causing a decrease in battery power.

For most Ei Electronics mains powered alarms a replacement kit is available - this contains an original Ei replacement alarm which is compatible with the old system and contains instructions on how to install. Installation is made fast and easy thanks to the easi-fit base (supplied), combined with simple detector head removal and replacement. The Ei146E Optical Smoke Alarm may operate as a standalone alarm or may be interconnected to other alarms via a wired or wireless system and when interconnected all alarms in the system will sound if a fire is detected. Interruptions of the mains power can be due to several reasons, including incorrect wiring (e.g. if the power supply comes from the lighting system and the alarm is incorrectly wired to the switched part of the circuit or when neutral/earth wiring are reversed), tripped fuses/circuit breakers, loose wires and general power failure. Electrical spikes can also cause false alarms or damage the smoke alarms. Smoke detector is off the ceiling and the battery has been removed but the beeping continues The radio interlinked smoke alarms of the Ei140 series alarms, while having been fitted by an electrician, are not interconnecting. Solution In an interlinked system when one unit detects smoke, all alarms sound. To silence the alarms in case of a false alarm, press the hush button on the unit that has detected the smoke. This will silence all interlinked alarms.Ei Electronics and Aico products have usually a 5 year manufacturer’s warranty during which they will be repaired or replaced free of charge if suffering from faults or defects caused by manufacturing issues. Aico’s telephone number is 01691 664100. They deal with warranty cases for the mains powered ranges. Smoke alarm starts to beep in the middle of the night Here are some common questions we have been asked by our customers about Ei Electronics and Aico (Ei’s UK operation) mains powered smoke alarms and heat alarms through our fire safety forum. You may find this range of videos, showing how to change batteries and detector heads, useful. We also offer replacement smoke detector heads so that you can change your alarm without the need to call in an electrician. General smoke alarm problems It would appear that the system has been house coded incorrectly or something is disturbing the signal. If the units have not yet been house coded, the instructions supplied with the unit should be followed to do this. In most situations this will resolve the problem.

How to stop beeping from Ei / Aico mains powered smoke and heat alarms Ei141, Ei144, Ei146, Ei150, Ei151, Ei154, Ei156, Ei161, Ei164, Ei166 The Ei146e may operate as a standalone Alarm or may be interconnected via hardwire to communicate with compatible Ei Alarms and accessories. Up to 20 devices can be interconnected. Interconnecting the Ei146e with the Ei1529RC enables the user to Locate, Silence and Test the Alarms remotely.The Aico EI146E is the perfect choice to protect landings, bedrooms, dining rooms, hallways, and living rooms as it is approved to the required BS EN14604:2005 standard. Aico EI146E Features Remove the alarm from its base and press the test button to drain the residual charge. Does the beeping stop? If not, you have a different alarm in the room that is beeping, e.g. a CO alarm with a low battery

For most Ei Electronics mains powered smoke alarms, a replacement kit is available containing a compatible smoke alarm, and in the case of Ei140 and Ei160 alarms, the new head just slides onto the existing base without the need for an electrician.If a smoke detector is removed from the base and the battery is also removed, the alarm might still hold some residual charge and beep for up to a minute. Pressing the test button for about 10 seconds will discharge the circuitry.